OAM - Operations, Administration, and Maintenance
Last Updated
Sep 03, 2026
OAM - Operations, Administration, and Maintenance OAM - Operations, Administration, and Maintenance OAM - Operations, Administration, and Maintenance Feature ICX 7150 ICX 7150-ES ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 Diagnostic error codes 08.0.60 10.0.10d 08.0.95 08.0.70 08.0.90 10.0.10f
-
OSPF - IPv4 Open Shortest Path First
Last Updated
Sep 03, 2026
OSPF - IPv4 Open Shortest Path First OSPF - IPv4 Open Shortest Path First OSPF - IPv4 Open Shortest Path First Feature ICX 7150 ICX 7150-ES ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 OSPF v2 08.0.61 No 08.0.95 08.0.70 08.0.90 No 10.0.00 Graceful restart In a stack configuration only. 08.0.61 No
-
Quality of Service (QoS)
Last Updated
Sep 03, 2026
Quality of Service (QoS) Quality of Service (QoS) Quality of Service (QoS) Feature ICX 7150 ICX 7150-ES ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 Scheduling and queuing: Strict Priority (SP), Weighted Round Robin (WRR), Combined SP and WRR, 8 priority queues 08.0.60 10.0.10d 08.0.95 08.0.70
-
Stacking
Last Updated
Sep 03, 2026
Stacking Stacking Stacking Feature ICX 7150 ICX 7250 ICX 7450 ICX 7550 ICX 7650 ICX 7750 ICX 7850 Building stacking: Secure-setup Secure-setup is replaced by Stack interactive-setup on all platforms beginning with release 8.0.90. Secure-setup is replaced by Stack interactive-setup for all platforms
-
Deleting an IP address from an interface configured as a tunnel source
Last Updated
Sep 03, 2026
remove the tunnel source from the tunnel interface then delete the IP address, as shown in the following example. ICX 7150 devices do not support tunnels. This task is not supported for ICX 7150 devices. device(config-if-e1000-1/1/3)# interface tunnel 8 device(config-tnif-8)# no tunnel source
-
Ability to Convert Standalone Switch to Stack
Last Updated
Sep 03, 2026
ICX 7150 stack, an ICX 7250 stack, an ICX 7450 stack, an ICX 7650 stack, or an ICX 7850 stack. From FI 09.0.00, the maximum stack size for ICX 7150 and ICX 7250 devices are limited to eight units in a stack. Editing the stack member Listing online switches of the same family and same switch group Click OK. If stack and switch are running different version of an image, an error message is displayed. Displaying Error Messsage
-
Layer 3 IPv4 Multicast Scaling Numbers
Last Updated
Sep 03, 2026
MSDP SA Cache MSDP Peer Maximum Maximum Maximum Maximum RUCKUS ICX 7150 2048 2048 Not supported Not supported RUCKUS ICX 7150-ES Not supported Not supported Not supported Not supported 8192 6144 6144 64 RUCKUS ICX 7550 6144 (all Profiles) 6144 (all Profiles) 6144 (all Profiles) 64 RUCKUS ICX 7850
-
Ability to Convert Standalone Switch to Stack
Last Updated
Sep 22, 2026
ICX 7150 stack, an ICX 7250 stack, an ICX 7450 stack, an ICX 7650 stack, or an ICX 7850 stack. From FI 09.0.00, the maximum stack size for ICX 7150 and ICX 7250 devices are limited to eight units in a stack. Editing the stack member Listing online switches of the same family and same switch group Click OK. If stack and switch are running different version of an image, an error message is displayed. Displaying Error Messsage
-
Deleting an IP address from an interface configured as a tunnel source
Last Updated
Sep 03, 2026
remove the tunnel source from the tunnel interface then delete the IP address, as shown in the following example. ICX 7150 devices do not support tunnels. This task is not supported for ICX 7150 devices. device(config-if-e1000-1/1/3)# interface tunnel 8 device(config-tnif-8)# no tunnel source
-
Supported ICX Firmware and Models
Last Updated
Sep 03, 2026
Supported ICX Firmware and Models Supported ICX Firmware and Models Supported ICX Firmware and Models ICX Firmware Versions Compatible with SmartZone ICX Model First Supported FastIron Release Last Supported FastIron Release ICX 7150 08.0.80a 09.0.10a and subsequent patches ICX 7150-C08P, -C08PT