show ip multicast optimization
Last Updated
Sep 03, 2026
. Privileged EXEC mode VLAN configuration mode The show ip multicast optimization command is available only on ICX 7250, ICX 7750, and ICX 7450 devices. Use this command to display the availability of IPMC group indexes in the hardware and how they are used and shared. The IPMC group index range
-
show ipv6 multicast optimization
Last Updated
Sep 03, 2026
. Privileged EXEC mode VLAN configuration mode The show ipv6 multicast optimization command is supported only on ICX 7250, ICX 7750, and ICX 7450 devices. Use this command to display the availability of L2MC group indexes in the hardware and how it is used and shared The L2MC group index range varies
-
show bfd vrf
Last Updated
Sep 03, 2026
Specifies OSPFv2. v6-neighbors Specifies IPv6 neighbor session information. ospf6 Specifies OSPFv3. User EXEC mode This command is supported for Ruckus ICX 7750 and ICX 7850 devices. The following example shows information about the applications that are registered to BFD for a non-default VRF
-
Configuring the share level for an ingress buffer profile
Last Updated
Sep 03, 2026
buffers that a priority group (PG) can use as a portion of the of the total sharing pool. Configuration of the ingress buffer share level is supported only on Ruckus ICX 7250, ICX 7450, and ICX 7750 devices. Enter global configuration mode. device# configure terminal Configure the share level. device
-
RUCKUS FastIron QoS and Traffic Management Configuration Guide, 09.0.10
Last Updated
Sep 03, 2026
ACLs to rate limit inbound CPU traffic. Unsupported hardware This release and future releases do not support ICX 7750 devices. References have been removed throughout the guide.
-
SPX configuration CB SPX port table
Last Updated
Sep 03, 2026
Brocade ICX 7750 devices. Name, OID, and syntax Access Description brcdSPXCBSPXPortTable brcdIp.1.1.3.40.2.3 Not-accessible The SPX configuration CB SPX port table. brcdSPXCBSPXPortPort brcdIp.1.1.3.40.2.3.1.1 Syntax: Integer32 Not-accessible The IfIndex for the configured CB SPX port. The CB unit
-
RUCKUS ICX Switch Port Extender Deployment Guide
Last Updated
Sep 02, 2026
Scaling (Supported Topologies) Scaling (Supported Topologies) Scaling (Supported Topologies) Scaled Topology Including SPX (PE) Ring and PE Chains Scalability Limits 4 CB stack units (ICX 7750) 36 PE units (ICX 7450, ICX 7250, and ICX 7150) 6 PE units per chain cascade depth 1500 PE ports 4 VLANs
-
map vlan (VXLAN)
Last Updated
Sep 03, 2026
segment ID). Overlay-gateway configuration mode The command is supported only on ICX 7750 devices. A maximum of 256 VLAN-to-VNI mappings can be configured. The designated VLAN must already have been configured. The default VLAN, VLAN 1, unless the default is reconfigured, cannot be mapped to a VNI. A
-
Campus Fabric Configuration Overview
Last Updated
Sep 03, 2026
configure a Campus Fabric domain, the following steps must be completed. Configure and connect two to four ICX 7650, ICX 7750, or ICX 7850 devices in a traditional stack, or configure a standalone ICX 7650, ICX 7750, or ICX 7850. Configuring two or more devices in a stack provides redundancy for the
-
Cut-through switching
Last Updated
Sep 03, 2026
(referred to as the switch's latency) is on the order of a few microseconds only, regardless of the packet size. Cut-through latency provides the latency details. The cut-through mode is supported on ICX 7750 and ICX 7850 devices. Default behavior on devices that support cut-through switching Supported