securewipe
Last Updated
Sep 03, 2026
supported on the ICX 7550, ICX 7650, and ICX 7850 (router) devices only. Powering down or power cycling the device during secure wipe may cause the device to fail and it will fail to reboot. Powering down or power cycling the device during secure wipe may cause a failure to connect to the cloud
-
securewipe
Last Updated
Sep 03, 2026
supported on the ICX 7550, ICX 7650, and ICX 7850 (router) devices only. Powering down or power cycling the device during secure wipe may cause the device to fail and it will fail to reboot. Powering down or power cycling the device during secure wipe may cause a failure to connect to the cloud
-
Log Manager
Last Updated
Sep 03, 2026
all the log files in a unit is restricted to 5 MB on the RUCKUS ICX 7150 and ICX 7150-ES devices, and 10 MB for the RUCKUS ICX 7550, 7650, 7850, and 8200 devices. Log Message Severity Levels The severity levels of the log messages are described in the following table. Log Message Severity Levels
-
Entity MIBs
Last Updated
Sep 03, 2026
1.3.6.1.4.1.1991.1.17.1.12.11 brcdEntityOIDCpuPPC8572E 1.3.6.1.4.1.1991.1.17.1.12.12 History Release version History 08.0.50 This MIB was introduced. 08.0.70 Introduced ICX 7650 Entity OIDs. 08.0.90 Introduced ICX 7850 Entity OIDs. 08.0.95 Introduced ICX 7550 Entity OIDs.
-
Secure Wipe
Last Updated
Sep 03, 2026
repeatedly through a specific number of passes, followed by verification at the end of the final pass. Secure wipe is supported on ICX 7550, ICX 7650, ICX 7850, ICX 8100, and ICX 8200 devices. There are three different types of secure wipes: Single Pass: Overwrites all addressable locations with a random
-
Secure Wipe
Last Updated
Sep 03, 2026
repeatedly through a specific number of passes, followed by verification at the end of the final pass. Secure wipe is supported on ICX 7550, ICX 7650, ICX 7850, ICX 8100, and ICX 8200 devices. There are three different types of secure wipes: Single Pass: Overwrites all addressable locations with a random
-
Secure Wipe
Last Updated
Sep 03, 2026
repeatedly through a specific number of passes, followed by verification at the end of the final pass. Secure wipe is supported on the ICX 7550, ICX 7650, and ICX 7850 (router) devices only. There are three different types of secure wipes: Single Pass: Overwrites all addressable locations with a random
-
MCT Recommendations and Best Practices
Last Updated
Sep 03, 2026
MCT configuration with stacking rings, after a standby controller goes down and comes back up, traffic loss may occur, including on ports from stack units other than the standby controller. In an MCT configuration with ICX 7550 or ICX 7850 peer stacks that includes a static LAG connection through a
-
clear overlay-gateway
Last Updated
Sep 03, 2026
OutKnownUcastBytes: 0 OutBumPkts : 0 OutBumBytes : 0 Bum Traffic consists Unknown Ucast, Mcast, Bcast Traffic Release version Command history 09.0.10b The command was introduced for ICX 7550, ICX 7650, and ICX 7850 devices.
-
RUCKUS FastIron RESTCONF Programmers Guide, 10.0.20
Last Updated
Sep 03, 2026