-
Specifying a Port Address
Last Updated
Sep 03, 2026
. Port: Specifies the port number in the slot. Specifying Data Port Address ICX Devices Unit/Slot/Port ICX 7850, ICX 7650, ICX 7550, ICX 7450, ICX 7250, ICX 7150 1/1/1 to 1/1/24 or 1/1/48 Specifying Stacking Port Address ICX Devices Unit/Slot/Port ICX 7850, ICX 7650, ICX 7550, ICX 7450, ICX 7250, ICX 7150 1/1/1 to 12/1/1 Specifying Management Port The management port number is always 1.
-
Maximum Number of LAGs
Last Updated
Sep 03, 2026
Valid Number of Ports in a Group Static LACP ICX 7150 128 128 1 to 8 The ICX 7150 can scale up to 1024 LAG ports and are also limited to the number of ports on the device. ICX 7250 ICX 7450 ICX 7550 ICX 7650 ICX 7750 ICX 7850 256 256 1 to 16 The ICX 7250, ICX 7450, ICX 7550, ICX 7650, OCX 7750 and ICX 7850 devices can scale up to a maximum of 2048 LAG ports.
-
Specifying a Port Address
Last Updated
Sep 03, 2026
. Port: Specifies the port number in the slot. Specifying Data Port Address ICX Devices Unit/Slot/Port ICX 7850, ICX 7750, ICX 7650, ICX 7550, ICX 7450, ICX 7250, ICX 7150 1/1/1 to 1/1/24 or 1/1/48 Specifying Stacking Port Address ICX Devices Unit/Slot/Port ICX 7850, ICX 7750, ICX 7650, ICX 7550, ICX 7450, ICX 7250, ICX 7150 1/1/1 to 12/1/1 Specifying Management Port The management port number is always 1.
-
Campus Fabric
Last Updated
Sep 03, 2026
extenders (PEs), or PE units, to a set of ICX 7650 stack units configured as the control bridge. The ICX 7650 control bridge (CB) provides a single point of management for the extended network. Active and standby controller functions are retained and continue to provide hitless recovery as well as
-
Campus Fabric Limitations for Image Downgrade from FastIron Release 08.0.90 to Previous Releases
Last Updated
Sep 03, 2026
Support for ICX Devices ICX device First FastIron release to support SPX on device SPX role ICX 7750 08.0.40 CB ICX 7450 08.0.40 PE ICX 7250 08.0.50 PE ICX 7150 08.0.70 PE ICX 7650 08.0.80 CB SPX System with ICX 7650 CB Units Downgrade from FastIron release 08.0.90 to 08.0.70 or prior releases is not
-
Registration MIB Definition
Last Updated
Sep 03, 2026
snFastIronStackICX7650 brcdIp.1.3.48.11 RUCKUS ICX 7650 Stack snFastIronStackICX7650Switch brcdIp.1.3.48.11.1 RUCKUS ICX 7650 Stack Switch snFastIronStackICX7650Router brcdIp.1.3.48.11.2 RUCKUS ICX 7650 Stack Router snFastIronStackICX7850 brcdIp.1.3.48.12 RUCKUS ICX 7850 Stack snFastIronStackICX7850Switch brcdIp
-
Registration MIB Definition
Last Updated
Sep 03, 2026
snFastIronStackICX7650 brcdIp.1.3.48.11 RUCKUS ICX 7650 Stack snFastIronStackICX7650Switch brcdIp.1.3.48.11.1 RUCKUS ICX 7650 Stack Switch snFastIronStackICX7650Router brcdIp.1.3.48.11.2 RUCKUS ICX 7650 Stack Router snFastIronStackICX7850 brcdIp.1.3.48.12 RUCKUS ICX 7850 Stack snFastIronStackICX7850Switch brcdIp
-
About Port Regions
Last Updated
Sep 03, 2026
ICX 8100 device has only one port region. All ports belong to region 0. ICX 7850 Device Port Regions ICX 7850 device has only one port region. All ports belong to region 0. ICX 7650 Device Port Regions ICX 7650 device has only one port region. All ports belong to region 0. ICX 7150 Device Port
-
Stacking by Device
Last Updated
Sep 03, 2026
capabilities. ICX 7650 Stack Configuration Overview The following table provides an overview of ICX 7650 stacking capabilities. ICX 7850 Stack Configuration Overview The following table provides an overview of ICX 7850 stacking capabilities. ICX 8200 Stack Configuration Overview The following table provides an overview of ICX 8200 stacking capabilities.
-
clear macsec statistics
Last Updated
Sep 03, 2026
interface on the slot. privileged EXEC mode MACsec commands are supported only on ICX 7450, ICX 7650, and ICX 7850 devices. In the following example, MACsec traffic statistics are cleared for interface 1/3/4 (port 4 of slot 3 on the first device in the stack). device# clear macsec statistics ethernet