⚠ This cached page may be outdated. Click refresh to get the latest content.
Cached Version You are Offline

You are viewing a cached version of this page.

You are currently offline. This page was loaded from cache.

Search Results: "icx 7650"

Showing 1,091 - 1,100 of 1,349 results

Relevance: best match to your search term first.

  • Selective QinQ

    Last Updated Sep 03, 2026

    devices must be running FastIron firmware version 10.0.20b_cd2 or later SmartZone must be running version 7.1.1 or later RUCKUS ICX models supported: ICX 7550, ICX 7650, ICX 7850, and ICX 8200 New CVLAN only supports the model ICX 8200 Considerations Consider the following when configuring and using this
  • Selective QinQ

    Last Updated Sep 03, 2026

    devices must be running FastIron firmware version 10.0.20b_cd2 or later SmartZone must be running version 7.1.1 or later RUCKUS ICX models supported: ICX 7550, ICX 7650, ICX 7850, and ICX 8200 New CVLAN only supports the model ICX 8200 Considerations Consider the following when configuring and using this
  • sflow sample

    Last Updated Sep 03, 2026

    that you do not change the denominator to a value lower than the default. Sampling requires CPU resources. Using a low denominator for the sampling rate can cause high CPU utilization. On RUCKUS ICX 7750, ICX 7450, ICX 7250, ICX 7650, ICX 7850, and ICX 7550 the CPU-bound sFlow sample packets are
  • Setting the Clock Parameters for the Device

    Last Updated Sep 03, 2026

    in the Real Time Clock (RTC) register even when power is removed from the device. However, the ICX 7650 devices do not have this capability because they were designed without an RTC battery, therefore they do not retain clock date and time in case of power outage. To avoid this, configure the NTP
  • Enabling DOM

    Last Updated Sep 03, 2026

    -monitor Enable optical monitoring and set alarm/warn interval to default(8 minutes) The default alarm interval for the ICX 7450, ICX 7550, ICX 7650, and ICX 7850 is 8 minutes. The default alarm interval for the ICX 7250 and ICX 7150 is 3 minutes. Ports that are down are not included for optical
  • DSCP-Based QoS Configuration

    Last Updated Sep 03, 2026

    VE interfaces and GRE tunnel interfaces on ICX 7850, ICX 7650, and ICX 7550 devices. On ICX 8100 and ICX 8200 devices, configuring both DSCP trust and Traffic Policy is not recommended. When DSCP trust and Traffic Policy are configured on the same interface, trust DSCP will not be honored on Layer 3
  • Enabling DOM

    Last Updated Sep 03, 2026

    for ICX 7150 devices. The default alarm interval for ICX 7150 is 3 minutes. device(config)# optical-monitor Enabled optical monitoring and set alarm/warn interval to default(3 minutes) The default alarm interval for ICX 7550, ICX 7650, ICX 7850, and RUCKUS ICX 8200 devices is 8 minutes. device
  • Configuration Notes for PVLANs and Standard VLANs

    Last Updated Sep 03, 2026

    domain. PVLAN Support Matrix Platform Forwarding Type Tagged Port Untagged Port ISL Port Multiple Promiscuous Port ICX 7150-ES Hardware Yes Yes Yes Yes ICX 7150 Hardware Yes Yes Yes Yes ICX 7550 Hardware Yes Yes Yes Yes ICX 7650 Hardware Yes Yes Yes Yes ICX 7850 Hardware Yes Yes Yes Yes ICX 8100 Hardware Yes Yes Yes Yes ICX 8200 Hardware Yes Yes Yes Yes
  • Configuration Notes for PVLANs and Standard VLANs

    Last Updated Sep 03, 2026

    domain. PVLAN Support Matrix Platform Forwarding Type Tagged Port Untagged Port ISL Port Multiple Promiscuous Port ICX 7150 Hardware Yes Yes Yes Yes ICX 7250 Hardware Yes Yes Yes Yes ICX 7450 Hardware Yes Yes Yes Yes ICX 7650 Hardware Yes Yes Yes Yes ICX 7850 Hardware Yes Yes Yes Yes
  • Configuration Notes for PVLANs and Standard VLANs

    Last Updated Sep 03, 2026

    private VLAN domain. PVLAN Support Matrix Platform Forwarding Type Tagged Port Untagged Port ISL Port Multiple Promiscuous Port ICX 7550 Hardware Yes Yes Yes Yes ICX 7650 Hardware Yes Yes Yes Yes ICX 7850 Hardware Yes Yes Yes Yes ICX 8100 Hardware Yes Yes Yes Yes ICX 8200 Hardware Yes Yes Yes Yes