-
PoE/PoE+ - Power over Ethernet
Last Updated
Sep 03, 2026
PoE/PoE+ - Power over Ethernet PoE/PoE+ - Power over Ethernet PoE/PoE+ - Power over Ethernet Feature Legacy inline power is not supported in 4-pair PoE ports. ICX 7150 ICX 7150-ES ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 Auto PoE firmware upgrade 08.0.70 10.0.10d 08.0.95 08.0.70 No 10.0.10f
-
debug bfd
Last Updated
Sep 03, 2026
Displays debugging information about the BFD state. vrf vrf-id Displays debugging information about BFD for the specified VRF. Privileged EXEC mode This command is supported for ICX 7850 device only. The following example displays debugging information about the BFD holdtime. device# debug bfd
-
BGP4 - IPV4 Border Gateway Protocol
Last Updated
Sep 03, 2026
BGP4 - IPV4 Border Gateway Protocol BGP4 - IPV4 Border Gateway Protocol BGP4 - IPV4 Border Gateway Protocol Feature ICX 7550 ICX 7650 ICX 7850 ICX 8100 ICX 8200 BGP4 08.0.95 08.0.70 08.0.90 No 10.0.20a BGP4 Graceful Restart 08.0.95 08.0.70 08.0.90 No 10.0.20a BGP4 Graceful Restart helper mode
-
1G Breakout Ports
Last Updated
Sep 03, 2026
subport irrespective of the type of optics. Speed settings are changed dynamically and do not require a reboot. Each breakout subport works according to its speed settings. The 1G Breakout Ports feature is supported on ICX 7850 and ICX 7550 switches only. The 1G Breakout Ports feature is supported with
-
Configuring a Port to the Egress Queue Drop Counters
Last Updated
Sep 03, 2026
configure the device to monitor a different port for packet drops. On the ICX 7550, ICX 7650, ICX 7850, ICX 8100, and ICX 8200 devices, each port has its own set of drop counters. This task is supported only on the ICX 7150 and ICX 7150-ES models. Perform the following steps to configure a port that the
-
31-Bit Subnet Masks on Point-to-Point Networks
Last Updated
Sep 03, 2026
31-Bit Subnet Masks on Point-to-Point Networks 31-Bit Subnet Masks on Point-to-Point Networks 31-Bit Subnet Masks on Point-to-Point Networks 31-bit subnet masks are supported on ICX 7150, ICX 7250, ICX 7450, ICX 7550, ICX 7650, and ICX 7850 devices running the full Layer 3 image. To conserve IPv4
-
Configuring Delay Time for Notifying VE Down Event
Last Updated
Sep 03, 2026
Layer 2 loop detection protocols. Suppressing the link status notification allows a quick port status change and recovery to occur without triggering any of the changes that are necessary when a port stays down. By default, the delay time is not configured. Configuring delayed Layer 3 notifications on the VE feature is supported on ICX 7150, ICX 7250, ICX 7450, ICX 7550, ICX 7650, and ICX 7850 product families from RUCKUS.
-
IPv6 PIM Convergence on MAC Address Movement
Last Updated
Sep 03, 2026
7550, ICX 7650, ICX 7850, and ICX 8200 devices. IPv6 PIM convergence on MAC address movement is applicable only when the multicast source and IPv6 PIM routers are in the same Layer 2 domain.
-
IPv6 PIM Convergence on MAC Address Movement
Last Updated
Sep 03, 2026
7250, ICX 7450, ICX 7550, ICX 7650, and ICX 7850 devices. IPv6 PIM convergence on MAC address movement is applicable only when the multicast source and IPv6 PIM routers are in the same Layer 2 domain.
-
debug bfd
Last Updated
Sep 03, 2026
Displays debugging information about the BFD state. vrf vrf-id Displays debugging information about BFD for the specified VRF. Privileged EXEC mode This command is supported for ICX 7850 device only. The following example displays debugging information about the BFD holdtime. device# debug bfd