key-server-priority
Last Updated
Sep 03, 2026
key-server priority. The possible values range from 0 to 255, where 0 is highest priority and 255 is lowest priority. dot1x-mka-cfg-group mode MACsec commands are supported only on ICX 7450, ICX 7650, and ICX 7850 devices. MACsec commands are supported only on ICX 7650 and ICX 7850 devices. The no
-
macsec confidentiality-offset
Last Updated
Sep 03, 2026
where encryption begins. Valid values are: 30: Encryption begins at byte 31 of the data packet. 50: Encryption begins at byte 51 of the data packet. dot1x-mka-cfg-group mode MACsec commands are supported only on ICX 7450, ICX 7650, and ICX 7850 devices. MACsec commands are supported only on ICX 7650
-
macsec frame-validation
Last Updated
Sep 03, 2026
packets are accepted. strict Enables validation checks for frames with MACsec headers and configures strict validation mode. If frame validation fails, counters are incremented and packets are dropped. dot1x-mka-cfg-group mode MACsec commands are supported only on ICX 7450, ICX 7650, and ICX 7850 devices
-
key-server-priority
Last Updated
Sep 03, 2026
key-server priority. The possible values range from 0 to 255, where 0 is highest priority and 255 is lowest priority. dot1x-mka-cfg-group mode MACsec commands are supported only on ICX 7450, ICX 7650, and ICX 7850 devices. MACsec commands are supported only on ICX 7650 and ICX 7850 devices. The no
-
system-max ip6-neighbor
Last Updated
Sep 03, 2026
system-max ip6-neighbor system-max ip6-neighbor system-max ip6-neighbor Configures the maximum number of IPv6 neighbors. system-max ip6-neighbor max-num-of-neighbors no system-max ip6-neighbor max-num-of-neighbors For ICX 7850 devices, the default is 4096. For all other platforms, the default is
-
Configuration Considerations for Forwarding Profiles
Last Updated
Sep 03, 2026
, IGMP groups, MLD groups, PIM mcache, PIMv6 mcache, and next hops take the value from the configured profile. The IP route default VRF, IP route VRF, IPv6 route VRF, and IPv6 default VRF are reset. The default forwarding profile is profile1. For ICX 7850 devices, there are four profiles available. For
-
Configuration Considerations for Forwarding Profiles
Last Updated
Sep 03, 2026
Configuration Considerations for Forwarding Profiles Configuration Considerations for Forwarding Profiles Configuration Considerations for Forwarding Profiles The following configuration considerations apply to Forwarding Profiles: Forwarding profiles are only supported on ICX 7850 and ICX 7550
-
Configuration Considerations for Forwarding Profiles
Last Updated
Sep 03, 2026
, IGMP groups, MLD groups, PIM mcache, PIMv6 mcache, and next hops take the value from the configured profile. The IP route default VRF, IP route VRF, IPv6 route VRF, and IPv6 default VRF are reset. The default forwarding profile is profile1. For ICX 7850 devices, there are four profiles available. For
-
system-max ip6-neighbor
Last Updated
Sep 03, 2026
system-max ip6-neighbor system-max ip6-neighbor system-max ip6-neighbor Configures the maximum number of IPv6 neighbors. system-max ip6-neighbor max-num-of-neighbors no system-max ip6-neighbor max-num-of-neighbors For ICX 7850 devices, the default is 4096. For all other platforms, the default is
-
system-max ip6-neighbor
Last Updated
Sep 03, 2026
system-max ip6-neighbor system-max ip6-neighbor system-max ip6-neighbor Configures the maximum number of IPv6 neighbors. system-max ip6-neighbor max-num-of-neighbors no system-max ip6-neighbor max-num-of-neighbors For ICX 7850 devices, the default is 4096. For all other platforms, the default is